PACCAR MX (2004 Emissions) Fault Code: P2147 Common Rail Pump Unit 1 – Voltage Too Low or Short Circuit to Ground on ECU (D420) Pin (A26)

Description

PACCAR MX (2004 Emissions) Fault Code: P2147 Common Rail Pump Unit 1 – Voltage Too Low or Short Circuit to Ground on ECU (D420) Pin (A26)

SET CONDITIONS:
This DTC is set when the ECU detects a lower voltage than expected on the signal or control circuit of the ECU.

DIAGNOSTIC CONDITION:
The diagnostic runs continuously when the ignition is keyed on.

CORRESPONDING OBD READINESS MONITOR:
None

RESET CONDITION:
The DTC changes to inactive after the diagnostic runs and passes.

REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful

POSSIBLE CAUSES:
1. The sensor or actuator signal wiring is interrupted.
2. The sensor or actuator signal wiring has a short circuit to ground.
3. A malfunction in the power supply of the sensor or actuator
4. A malfunction of the sensor or actuator

ADDITIONAL INFORMATION:
When this DTC is active:
1. The engine torque is reduced.
2. The engine runs in protection mode.
3. The maximum rail pressure is limited to 1300 bar.