Welcome to DTCTRUCK.COM ! Wrap new offers / gift every single day on Weekends – New Coupon code: DTCTRUCK2023

Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3597 FMI 4 (MCM) Proportional Valve Bank 1 Circuit Failed Low

Description

PROBABLE CAUSES:

For 2007 EPA Engines:
1. Engine brake solenoid.
2. Short to ground between pin 91 of the ECM 120-pin connector and the valve cover fuel injector harness connector (31-pin connector).
3. Short to ground between pin 22 of the 31-pin connector on the vehicle side of he harness and the fan control solenoid.
4. Short to ground between pin 93 of the ECM 120-pin connector and the air seal pressure regulator valve cover.
5. Failed air seal pressure regulator valve.

For 2010 EPA Engines:
1. Inspect the connectors on: DEF pump, pressure limiting unit, diffuser heater, and DEF injection valve.
2. ACM2 (Aftertreatment Control Module) failure.
3. Short to ground between pins 1, 3, or 5 of the ACM2 and pin 2 of the corresponding components.
4. Reconnect components from line #1 one at a time and clear the code after each connection. When the code goes active, this is your failed part.

For 2014 EPA Engines:
1. Engine Jake brake solenoid failure.
2. Front under valve cover fuel injector harness.
3. Short to ground between pin 91 of the 120-pin ECM connection and the valve cover fuel injector harness connector (31-pin).
4. Short to ground between pin 22 of the 31-pin connector on the vehicle side of the harness and fan control solenoid.
5. Short to ground between pin 93 of the 120-pin ECM connection and the air seal pressure regulator valve connector.
6. Air seal pressure regulator valve.

Reviews

There are no reviews yet.

Be the first to review “Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3597 FMI 4 (MCM) Proportional Valve Bank 1 Circuit Failed Low”

Your email address will not be published. Required fields are marked *

x