DESCRIPTION:
High side digital output 1 circuit short to power.
MONITORED PARAMETER:
High side digital output 1 circuit.
TYPICAL ENABLING CONDITIONS:
Always on
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
One second
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
VERIFICATION:
Ignition key cycle.
PROBABLE CAUSES:
For 2010 EPA Engines:
1. Short to power between pin 1 of the Jake brake solenoid and pin 66 of the MCM 120-pin connector.
2. Short to power between pin 2 of the Jake brake solenoid and pin 91 of the MCM 120-pin connector.
For 2014 EPA Engines:
1. DEF Dosing unit harness connector.
2. Short to battery voltage between pin 4 of the harness side of the DEF dosing unit harness connector and pin 3 of the ECM 120-pin connector.
3. Short between pin 3 of the harness side of the DEF dosing unit harness connector and pin 22 of the ECM 120-pin connector.