DESCRIPTION:
Diesel Exhaust Fluid (DEF) pressure relief valve stuck closed.
MONITORED PARAMETER:
DEF Pressure
TYPICAL ENABLING CONDITIONS:
When service routine is enabled and during in-use checks under non-dEF dosing conditions.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Service tool and during in-use checks under non-DEF dosing conditions.
TYPICAL DURATION:
2 Seconds
DASH LAMPS:
None
ENGINE REACTION:
None
VERIFICATION:
SCR ADS self-check.
NOTE: If any other codes are active, fix those first.
PROBABLE CAUSES:
1. Inspect the DEF dosing unit and DEF pump harness wiring & connectors.
2. Check all DEF lines for damage/blocks/kinks.
3. DEF pump suction filter.
4. DEF dosing unit inlet filter.
5. DEF tank header.
6. DEF tank supply filter.
7. Replace the pressure relief valve.