Welcome to DTCTRUCK.COM ! Wrap new offers / gift every single day on Weekends – New Coupon code: DTCTRUCK2023

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4752 FMI 31 (MCM) Exhaust Gas Recirculation Cooler Performance Monitor

Description

DESCRIPTION:
Exhaust Gas Recirculation (EGR) cooler performance monitor.

MONITORED PARAMETER:
Intake manifold temperature sensor.

TYPICAL ENABLING CONDITIONS:
1. Engine running greater than 5 minutes.
2. EGR mass flow greater than .08.
3. Intake manifold temperature less than 125°C (257°F).
4. Engine speed 1200-2500 rpm.
5. Engine torque 500-2500 N·m.
6. Coolant temperature greater than 65°C (149°F).
7. Ambient temperature less than 45°C (113°F) ambient.
8. Coolant temperature greater than 65°C (149°F).
9. Ambient temperature greater than -8°C (17.6°F) ambient.
10. Barometric pressure greater than 755 mbar (10.95 psi).

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
30

DASH LAMPS:
MIL

VERIFICATION:
1. When ambient temperature less than 45°C (113°F).
2. Start engine.
3. Warm up such that coolant temperature greater than 65°C (149°F).
4. Ensure ambient barometric pressure greater than 755 mbar (10.95 psi).

PROBABLE CAUSES:
1. If there are any cooling system issues, repair those first.
2. Intake manifold air temperature sensor.
3. Intake manifold air temperature sensor connector/harness.
4. EGR system leaks.
5. Remove the EGR hot pipe, EGR crossover tube, and mixer pipe. If blockage found, replace the EGR Cooler.

Reviews

There are no reviews yet.

Be the first to review “Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4752 FMI 31 (MCM) Exhaust Gas Recirculation Cooler Performance Monitor”

Your email address will not be published. Required fields are marked *